ELECTRICAL ENGINEERING SERVICES
SERVICES
TRANSFORMER TESTING
-
Bushing Power Factor
-
Overall Power Factor
-
Core Excitation
-
Leakage Reactance
-
Turns Ratio
-
Sweep Frequency Response Analysis
-
Winding Resistance
-
Insulation Resistance
-
Oil Screen Test
-
Dissolved Gas Analysis
-
Generator Step Up
-
Substation
-
Distribution
-
Pad Mounted
-
Conservator Type
-
Arc Furnace
-
Instrument
-
Grounding
SWITCHGEAR TESTING
-
Power Factor
-
Insulation Resistance
-
Contact Resistance
-
Trip Coil Characteristic
-
Close Coil Characteristic
-
Motion and Travel
-
Timing
INSULATING OIL TESTING
Assessment of the physical and chemical properties of insulating oil
Dielectric Breakdown
Acidity
Interfacial Tension
Karl Fischer Moisture
Colour Index
Same day turn around avaliable.
INFRARED THERMOGRAPHY
-
Most problems go undetected until there is an operating failure. Electrical thermography is useful as there is no other preventative maintenance technology or technique that can identify defects such as poorconnections, over loaded cables and faulty electrical equipment as safely and as quickly, whilst causing no interruption to the normal operation of your business.
-
What Electrical Distribution Equipment should have Thermographic Inspections?
-
Substations, Transformers, Feed Poles, Power Distribution Systems, Main Switchboards, Disconnects, Service Disconnects for Motors, Machine Control Panels
GROUND RESISTANCE TESTING
Testing of Ground Systems in accordance with IEEE80 and other international standards.
-
Determination of Soil Resistivity
-
Measure of Rod Resistivity and Resistance to Remote Earth
-
Verify Integrity of System Connections
-
Validate Simulation Outputs
-
Electrical Substations
-
Industrial Plants
-
Petrochemical Plants
-
Commerical Facilites
-
Refineries
-
Data Centers
-
Hospitals
POWER QUALITY ANALYSIS & MONITORING
Studies and Investigations per IEEE 1159
-
Circuit Breaker Tripping
-
Relay Operation
-
Motor Overheating
-
Flickering Lights
-
Loss of Data
-
Damage to Sensitive Equipment
-
Damage Circuit Boards
-
Overloaded Circuits and Transformers
-
Inconsistent billing
-
Sags/Swells
-
Overvoltages/Undervoltages
-
Transients
-
Imbalances
-
Fluctuations
-
Harmonicas/Interharmonics
RELAY TESTING
-
Over and Under Current
-
Over and Under Voltage
-
Over and Under Frequency
-
Reverse Power
-
Transformer Differential
-
Motor Differential
-
Negative Sequence
-
Locked Rotor
-
Mechanical Jam
-
Loss of Excitation Synchronization
-
Loss of Excitation
-
Other Protective Functions
Schweitzer Engineering Laboratories, GE Multilin, ABB, Cutler Hammer, Siemens, Basler, Westinghouse, Beckwith, Schneider
HIGH VOLTAGE GLOVE TESTING
-
Physical Inspection
Assessment of the physical condition of both the leather protector and rubber insulating glove, including checks for mechanical and chemical damage, aging and degradation of rubber material internally and externally.
-
Electrical Withstand
Water soak and electrical withstand test as prescribed by OSHA 1910.137
-
Reporting
Reports are generated for each pair sent to our lab. All electrical and visual inspections are logged and reported. Unique test report for each pair of glove including customer provided identifier.
Standard turn around time, 5 days.
ONLINE PARTIAL DISCHARGE TESTING
Assess equipment which plant is running no need for downtime
-
Outdoor Substations
-
Circuit Breakers
-
Transformers
-
Surge Arrestors
-
Current Transformers
-
Voltage Transformers
-
Insulators
-
Cable Terminations
-
Indoor Switchgear
-
Switchgear Bus
-
Medium Voltage Cables
-
Cable Splices
ONLINE MOTOR CURRENT SIGNATURE ANALYSIS
Assess condition on motors while plant is running.
No need for downtime to assess Motor and Load.
-
Power System Deficiences
-
Voltage Imbalance
-
Current Imbalance
-
Voltage Harmonics
-
Rotor Bar Conditions
-
Rotor Static Eccentricity
-
Rotor Dynamic Eccentricity
-
Bearing Wear
-
Coupling Defects
ABOUT
From subcircuit to the substation, Shamco Limited is the Caribbean's premier provider of solution based electrical engineering services. Founded in 2002, Shamco Limited continues to be dedicated to the application of the fundamentals of engineering in assessing and solving problems for our clients. Investments in training, development, state of the art equipment and systems, are evidence of our commitment to premier service. Shamco Limited is the first private company to own the Doble M4000 and TDR900 in the Eastern Caribbean and to perform SFRA using the Doble M5400. Now we are the first to go 100% cloud-based. Our customers can trust that not only we have the best people, equipment, and systems, but their information is both safe and available at any time and from anywhere.
At Shamco, the future is now.
2002
Year Established
PROJECTS
CONTACT
Head Office
97 Uriah Butler Highway
Charlieville
Trinidad and Tobago
Email: admin@shamcolimited.com
Tel: 868 672 1252
Fax: 868 665 0571